ISOLATEK Type 400 AC

ISOLATEK Type 400 AC is a gypsum based, wet mix, medium density Spray-Applied Fire Resistive Material (SFRM) designed to be used with the ISOLATEK QWIK-SET ® system.

Category:

PRODUCT DESCRIPTION

ISOLATEK Type 400 AC is a gypsum based, wet mix, medium density Spray-Applied Fire Resistive Material (SFRM) designed to be used with the ISOLATEK QWIK-SET ® system. ISOLATEK Type 400 AC provides fire protection for structural steel in commercial and high rise construction to interior conditioned areas which may be subjected to higher levels of abuse such as mechanical and electrical rooms or elevator shafts. ISOLATEK Type 400 AC offers enhanced strength and durability and meets the current IBC high rise bond strength requirement of ≥ 430 psf and 1,000 psf.

In addition to fire resistance, ISOLATEK Type 400 AC also provides thermal benefits. As a thermal insulator, it is effective in reducing heat loss, particularly when applied to the underside of a roof deck. The R-value added by ISOLATEK Type 400 AC may also allow a reduction in roof insulation.

Combining its fire resistive ratings, thermal insulating properties, and application efficiencies, ISOLATEK Type 400 AC is the most innovative, wet mix, medium density SFRM on the market today.

PRODUCT ADVANTAGES

  • Offers the most cost effective fire resistance performance per unit thickness and greatest productivity of any medium density SFRM
  • Less material is needed to achieve required fire ratings
  • Meets or exceeds industry in-place performance standards
  • Provides added value as a thermal insulator
  • Cost effective, clean and neat in appearance

FIRE TEST PERFORMANCE

ISOLATEK Type 400 AC has been evaluated for fire resistance and is rated for up to 4 hours for floor assemblies, beams, joists, columns, and roof assemblies.

  • Classified by UL in accordance with ANSI/UL 263 (ASTM E119)
  • Classified by UL in accordance with CAN/ULC-S101 (ASTM E119)

ISOLATEK Type 400 AC has also been tested for surface burning characteristics in accordance with ASTM E84 and is rated Class A.

Flame Spread …….0     Smoke Developed …….0

CODE COMPLIANCES

ISOLATEK Type 400 AC satisfies the requirements of the following:

  • IBC ® – INTERNATIONAL BUILDING CODE ®
  • City of Los Angeles (LADBS, Category 1 Material)
  • NBC – National Building Code of Canada
  • ICC-ES, AC23 and AC10 Requirements (UL ER13348-01)

MAJOR SPECIFICATIONS

ISOLATEK Type 400 AC complies with the requirements of the following specifications:

  • MasterSpec ® , Section 078100 APPLIED FIREPROOFING (AIA)
  • MasterFormat ® 2014, Section 07 81 00 Applied Fireproofing (CSC,CSI)
  • Unified Facilities Guide Specification, UFGS 07 81 00 Spray-Applied Fireproofing (USACE, NAVFAC, AFCEC, NASA)
  • Master Construction Specifications, Number 07 81 00 Applied Fireproofing (VA)
  • Code of Federal Regulations, Title 40 Protection of the Environment (EPA)
  • PBS-P100, Facilities Standards for the Public Buildings Services (GSA)